TASC VISTA Thermal Analysis by Surface Characterisation
Specification:TASC VISTA Thermal Analysis by Surface Characterisation
A visual approach to materials characterization
Image Station
1. Linkam temperature microscope dedicated microscope stage。
2. The upper seat can be tilted backwards for easy disassembly of the platform。
3. The camera is mounted directly above the objective lens to prevent multiple reflections from affecting the image quality。
4. 20 LED Array Lighting。
5. Can add polarizing module。
6. 5 megapixel CMOS camera with a maximum resolution of 2448 X 2048。
7. All brands of objective lenses can be used。
Link Software
1. Complete Linakm system operator interface
2. Real-time display of parameters such as temperature and pressure surface shearing (other than temperature, other physical properties need to be matched with a specific stage)
3. Use with Image Station to extend Image Capture, TASC (Thermal Analysis by Surface Characterization)
Image Capture
1. Image capture and measurement functions in LINK。
2. Users can freely set the interval of taking pictures or take pictures at special temperatures。
3. Temperature data can be directly marked in photos。 (See video below)
* LINK software has no photography function, but it is enough to integrate multiple photos into
。
TASC (Thermal Analysis by Surface Characterization)
1. TASC is the analysis of the thermodynamic properties of high electrons through shadow analysis.。
2. Detecting high polymer properties such as glass transition temperature, melting point, etc. by surface surface transition。
3. Different from the traditional DSC analysis method, TASCT can be used for trace or regional analysis.。
4. TASC analyzes the surface shape through software, and can respond sensitively even at a small temperature ladder。
5. Just use Image Station, no need to modify the heating stage, you can use this function。
6. If equipped with a DSC-capable stage, DSC and TASC analysis results can be displayed simultaneously。
Linkam Scientific diverse measurement equipment
1. Standard variable temperature system (-196 – 600 oC)
2. Ultra-high temperature variable system (room temperature – 1500 oC)
3. High pressure system (up to 600 bar, -196 – 600 oC)
4. Vacuum system (10 (10-3mbar, -196 – 350 oC)
5. Humidity control module (5% -90% RH)
6. Conductive probe system (up to 8 probes, maximum temperature control range -
196 – 600oC)
7. Rheometer system (-50 – 450 oC)
8. Surface tension measurement system (-196 – 350 oC)
9. DSC measurement system (-196 – 600 oC)